Low Voltage >> Fire Alarm


 Type FPLR

TYPE FPLR FIRE ALARM RISER CABLE - 300 Volt, PVC Insulation, PVC Jacket, Solid or Stranded Conductor, 75°C DRY

Fire Alarm Riser Cable is for indoor use for power limited fire alarm and communications cable for riser or non-riser applications. This cable is designed for fire alarm, smoke detectors, signaling, fire protective circuits. Constructed of PVC insulation and red PVC jacket, the cable is available either shielded or unshielded.

  • For riser or non-riser applications
  • Red jacketed cable
  • Sun resistant
  • Available shielded or unshielded
  • UL 1424 - Type FPLR
  • Constructed in accordance with UL Standard 1424
  • Complies with UL 1666 Vertical Shaft (riser) Flame Test
  • Complies with UL 910
  • Maximum continuous conductor temperature: 75°C DRY

  • PrintRequest

    Type FPLR
    Application: Fire Alarm, smoke detectors, signaling, fire protective circuits
     Type NPLFR

    TYPE NPLFR NON-POWER LIMITED FIRE ALARM CABLE - 150 Volt, PVC Insulation, PVC Jacket, Solid or Stranded Conductor, 90°C DRY

    Non-Power Limited Fire Alarm Cable is for indoor use in vertical runs that penetrate more than one floor. This cable is designed for use with fire alarm, smoke detectors, signaling, fire protective circuits operating at 150 volts or less. Constructed of PVC insulation and red PVC jacket, the cable is available either shielded or unshielded.

  • For vertical runs that penetrate more than one floor
  • Red jacketed cable
  • Available shielded or unshielded
  • Meets the requirements of NEC Article 760 and UL Standard No 1425
  • Maximum continuous conductor temperature: 90°C DRY

  • PrintRequest

    Type NPLFR
    Application: Fire/life safety systems, fire and alarm notification, smoke/heat detection, building control circuits and initiating circuit systems
     Type FPLP

    TYPE FPLP PLENUM FIRE ALARM CABLE - 300 Volt, LSPVC Insulation, LSPVC Jacket, Solid or Stranded Conductor, 60°C DRY

    Plenum Fire Alarm Cable is for indoor use within ducts, plenums, and other spaces used for environmental air for fire/life safety systems, fire and alarm notification, smoke/heat detection, building control circuits and initiating circuit systems. The cable is constructed of solid or stranded copper conductors with low smoke PVC (LSPVC) insulation and an overall low smoke PVC (LSPVC) jacket.

  • For installation within ducts, plenums & other spaces used for environmental air
  • Red LSPVC jacket
  • Available shielded or unshielded
  • UL listed NEC type FPLP
  • Constructed in accordance with UL Standard 1424
  • Complies with UL 910
  • Maximum continuous conductor temperature: 60°C DRY

  • PrintRequest

    Type FPLP
    Application: Fire/life safety systems, fire and alarm notification, smoke/heat detection, building control circuits and initiating circuit systems
     Type NPLFP

    TYPE NPLFP PLENUM NON-POWER LIMITED FIRE ALARM CABLE - 150 Volt, FEP Insulation, FEP Jacket, Solid or Stranded Conductor, 150°C DRY

    Plenum Fire Alarm Cable is for indoor use within ducts, plenums, and other spaces used for environmental air for fire/life safety systems, fire and alarm notification, smoke/heat detection, building control circuits and initiating circuit systems operating at 150 volts or less.

  • For installation within ducts, plenums,& other spaces used for environmental air
  • Red jacketed cable
  • Intended for NPLF systems operating at 150 volts or less
  • Available shielded or unshielded
  • UL 1425 - Type NPLFP
  • Constructed in accordance with NEC Article 760
  • Complies with UL 910
  • Maximum continuous conductor temperature: 150°C DRY

  • PrintRequest

    Type NPLFP
    Application: Fire protective signaling circuits