Transportation >> Automotive


 Automotive Cables for Toyota


PrintRequest

Automotive Cables for Toyota
Application:
 Automotive Cables for DaimlerChrysler


PrintRequest

Automotive Cables for DaimlerChrysler
Application:
 Type SGT Ground or Battery Cable

TYPE SGT (STARTER OR GROUND) CABLE - 50 Volt, PVC Insulation, Stranded Conductor, 80°C or 105°C

Type SGT (starter or ground) cable is constructed with soft-annealed, flexible, stranded copper and insulated with high-quality thermoplastic. The SGT standard is for battery, starter and ground cable intended for use at 50 volts or less in surface vehicle electrical systems of automobiles, boats, buses, RVs, trailers and trucks.

  • Available in standard battery circuit colors of black and red
  • Meets Ford M1L-56A and Chrysler MS-3450 specifications
  • Maximum continuous conductor temperature: 80°C or 105°C

  • PrintRequest

    Type SGT Ground or Battery Cable
    Application: Starter or battery ground circuits in surface vehicle electrical systems
     Type SXL Ground or Battery Cable

    TYPE SGX (STARTER OR GROUND) CABLE - 50 Volt, XLP Insulation, Stranded Conductor, 125°C

    Type SGX (starter or ground) cable is constructed with soft-annealed, flexible, stranded copper and insulated with high-quality cross-linked polyethylene (XLP). The SGX standard is for battery, starter and ground cable intended for use at 50 volts or less in surface vehicle electrical systems of automobiles, boats, buses, RVs, trailers and trucks where resistance to abrasion, heat and aging is desirable per SAE J1127.

  • Resistant to abrasion, heat and aging
  • Meets Ford QVM standards
  • Conforms to SAE specification J1127
  • Maximum continuous conductor temperature: 125°C

  • PrintRequest

    Type SXL Ground or Battery Cable
    Application: Starter or battery ground circuits
     Type GXL Primary Wire

    TYPE GXL AUTOMOTIVE PRIMARY WIRE - 50 Volt, XLP Insulation, Stranded Conductor, 125°C

    Type GXL cable is constructed with soft-annealed, flexible, stranded copper and insulated with high-quality cross-linked polyethylene (XLP). The GXL standard is for use in engine compartments in surface vehicle electrical systems of automobiles, boats, buses, RVs and trucks where higher heat resistance is required according to SAE J1128.

  • Resistant to high heat
  • Available in solid colors and stripes
  • Meets Ford M1L-85B and Chrysler MS-8900)specifications
  • Conforms to SAE J1128
  • Maximum continuous conductor temperature: 125°C

  • PrintRequest

    Type GXL Primary Wire
    Application: Engine compartments of automobiles, boats, buses, RVs and trucks
     Type TXL Extra-Thin Primary Wire

    TYPE TXL AUTOMOTIVE PRIMARY WIRE - 50 Volt, XLP Insulation, Stranded Conductor, 125°C

    Type TXL cable is constructed with soft-annealed, flexible, stranded copper and insulated with high-quality cross-linked polyethylene (XLP). The TXL extra-thin cable is for use in automotive electrical applications where small diameter and minimal weight is desirable. The cable is designed for surface vehicle electrical systems of automobiles, boats, buses, RVs and trucks where higher heat resistance is required according to SAE J1128.

  • Resistant to high heat
  • Extra-thin construction
  • Available in solid colors and stripes
  • Meets Ford M1L-123A and Chrysler MS-8288
  • Conforms to SAE J1128
  • Maximum continuous conductor temperature: 125°C

  • PrintRequest

    Type TXL Extra-Thin Primary Wire
    Application: Automotive applications where small diameter and minimal weight is desirable
     Type GPT Primary Wire

    TYPE GPT AUTOMOTIVE PRIMARY WIRE - 50 Volt, PVC Insulation, Stranded Conductor, 85°C

    Type GPT cable is constructed with soft-annealed, flexible, stranded copper and insulated with high-quality thermoplastic. The GPT cable is for use in automotive electrical applications where general circuit wiring is required. The cable is designed for surface vehicle electrical systems of automobiles, boats, buses, RVs and trucks where higher heat resistance is required according to SAE J1128.

  • Available in solid colors and stripes
  • Meets Ford Ml L-56A and Chrysler MS-3450 specifications
  • Conforms to SAE J1128
  • Maximum continuous conductor temperature: 85°C

  • PrintRequest

    Type GPT Primary Wire
    Application: Automotive general circuit wiring
     Type TWP Extra-Thin Primary Wire

    TYPE TWP EXTRA-THIN AUTOMOTIVE PRIMARY WIRE - 50 Volt, PVC Insulation, Stranded Conductor, 85°C

    Type TWP cable is constructed with soft-annealed, flexible, stranded copper and insulated with high-quality thermoplastic. The TWP extra-thin cable is for use in automotive electrical applications where general circuit wiring is required. The cable is designed for surface vehicle electrical systems of automobiles, boats, buses, RVs and trucks where higher heat resistance is required according to SAE J1128.

  • Extra-thin construction
  • Available in solid colors and stripes
  • Meets Ford MlL-120A and Chrysler MS-7889 specifications
  • Conforms to SAE J1128
  • Maximum continuous conductor temperature: 85°C

  • PrintRequest

    Type TWP Extra-Thin Primary Wire
    Application: Automotive general circuit wiring
     Type HDT Heavy-Duty Primary Wire

    TYPE HDT HEAVY-DUTY AUTOMOTIVE PRIMARY WIRE - 50 Volt, PVC Insulation, Stranded Conductor, 85°C

    Type HDT Cable is constructed with soft-annealed, flexible, stranded copper and insulated with high-quality thermoplastic. The HDT Cable is for use in automotive electrical applications where greater physical protection is required. The cable is designed for surface vehicle electrical systems of automobiles, boats, buses, RVs and trucks where higher heat resistance is required according to SAE J1128.

  • Available in solid colors and stripes
  • Meets Ford M1L-50A and Chrysler MS-3494 specifications
  • Conforms to SAE J1128
  • Maximum continuous conductor temperature: 85°C

  • PrintRequest

    Type HDT Heavy-Duty Primary Wire
    Application: Automotive general circuit wiring
     PVC Brake Cable

    PVC BRAKE CABLE - 50 Volt, PVC Insulation, Stranded Conductor, 85°C

    PVC Brake Cable is constructed of parallel GPT primary conductors which consists of soft-annealed, flexible, stranded copper and insulated with high-quality thermoplastic. Parallel construction is common for use with trailers and vehicles where space is limited.

  • Constructed of parallel GPT primary conductors
  • Offers protection against moisture and abrasion
  • Maximum continuous conductor temperature: 85°C

  • PrintRequest

    PVC Brake Cable
    Application: Truck, automotive, trailer or marine applications


    Specifications listed are from multiple manufacturers. The items above represent only a portion of the products available. For specific manufacturer technical information or for an item not shown, please contact a Calvert Wire cabling specialist at 800-837-2668.